Skip to main content

Table 3 The results detected by MLPA, CMA, and CNVplex®

From: A modified multiplex ligation-dependent probe amplification method for the detection of 22q11.2 copy number variations in patients with congenital heart disease

  Laboratory results
MLPA CMA CNVplex®
P1 chr22:19171011-21351601 loss chr22:18648866-21465659 loss chr22:18893757-21464055 loss
P2 chr22:19171011-21351601 loss chr22:18916842-21798907 loss chr22:18893757-21464055 loss
P3 chr22:19171011-21351601 loss chr22:18916842-21798907 loss chr22:18893757-21464055 loss
P4 chr22:19171011-21351601 loss chr22:18648866-21465659 gain chr22:18893757-21464055 loss
P5 chr22:19171011-21351601 loss chr22:18916842-21465662 loss chr22:18893757-21464055 loss
P6 chr22:22312856-22330186 gain chr22:22311348-22578983 gain chr22:22312856-22330186 gain
P7 chr22:19171011-21351601 loss chr22:18916842-21800797 loss chr22:18893757-21464055 loss
chr22:22312856-22330186 gain chr22:22311348-22578983 gain chr22:22312856-22330186 gain
P8 chr22:19171011-21351601 loss chr22:18916842-21798907 loss chr22:18893757-21464055 loss
P9 chr22:19171011-21351601 loss chr22:18916842-21041014 loss chr22:18893757-20940053 loss