Skip to main content

Table 2 The filtration efficiency and running time of the SGM filtering algorithm with various settings of the error tolerance ε from 0 to 0.05 Da and fixed parameter settings α=350, β=250, δ=900, and λ=∞ are compared on the EC data set

From: A graph-based filtering method for top-down mass spectral identification

Error tolerance (Da)

Filtration efficiency

Running time (ms)

0

8.04%

1.64

0.01

31.14%

4.81

0.02

33.07%

7.87

0.03

31.30%

14.03

0.04

29.47%

20.62

0.05

28.19%

25.58